Surface Navigation and the Influence of Navigation on MIS Surgery. Academic Article uri icon

Overview

abstract

  • STUDY DESIGN: Literature review. OBJECTIVES: To review the evidence for surface-based navigation in minimally-invasive spine surgery (MIS), provide an outline for its workflow, and present a wide range of MIS case examples in which surface-based navigation may be advantageous. METHODS: A comprehensive review of the literature and compilation of findings related to surface-based navigation in MIS was performed. Workflow and case examples utilizing surface-based navigation were described. RESULTS: The nascent literature regarding surface-based intraoperative navigation (ION) in spine surgery is encouraging and initial studies have shown that surface-based navigation can allow for accurate pedicle screw placement and decreased operative time, fluoroscopy time, and radiation exposure when compared to traditional fluoroscopic imaging. Surface-based navigation may be particularly useful in MIS cervical and lumbar decompressions and MIS lumbar instrumentation cases. CONCLUSIONS: Overall, it is possible that surface-based ION will become a mainstay in the armamentarium of enabling technologies utilized by minimally-invasive spine surgeons, but further studies are needed assessing its accuracy, complications, and cost-effectiveness.

publication date

  • April 1, 2022

Identity

PubMed Central ID

  • PMC8998479

Scopus Document Identifier

  • 85128356440

Digital Object Identifier (DOI)

  • 10.1177/21925682211028587

PubMed ID

  • 35393880

Additional Document Info

volume

  • 12

issue

  • 2_suppl