Time-demand, Radiation Exposure and Outcomes of Minimally Invasive Spine Surgery With the Use of Skin-Anchored Intraoperative Navigation: The Effect of the Learning Curve. Academic Article uri icon

Overview

abstract

  • STUDY DESIGN: Retrospective review. OBJECTIVE: The aim was to evaluate the learning curve of skin-anchored intraoperative navigation (ION) for minimally invasive lumbar surgery. SUMMARY OF BACKGROUND DATA: ION is increasingly being utilized to provide better visualization, improve accuracy, and enable less invasive procedures. The use of noninvasive skin-anchored trackers for navigation is a novel technique, with the few reports on this technique demonstrating safety, feasibility, and significant reductions in radiation exposure compared with conventional fluoroscopy. However, a commonly cited deterrent to wider adoption is the learning curve. METHODS: Retrospective review of patients undergoing 1-level minimally invasive lumbar surgery was performed. Outcomes were: (1) time for ION set-up and image-acquisition; (2) operative time; (3) fluoroscopy time; (4) radiation dose; (5) operative complications; (6) need for repeat spin; (7) incorrect localization.Chronologic case number was plotted against each outcome. Derivative of the nonlinear curve fit to the dataset for each outcome was solved to find plateau in learning. RESULTS: A total of 270 patients [114 microdiscectomy; 79 laminectomy; 77 minimally invasive transforaminal lumbar interbody fusion (MI-TLIF)] were included. (1) ION set-up and image-acquisition: no learning curve for microdiscectomy. Proficiency at 23 and 31 cases for laminectomy and MI-TLIF, respectively. (2) Operative time: no learning curve for microdiscectomy. Proficiency at 36 and 31 cases for laminectomy and MI-TLIF, respectively. (3) Fluoroscopy time: no learning curve. (4) Radiation dose: proficiency at 42 and 33 cases for microdiscectomy and laminectomy, respectively. No learning curve for MI-TLIF. (5) Operative complications: unable to evaluate for microdiscectomy and MI-TLIF. Proficiency at 29 cases for laminectomy. (6) Repeat spin: unable to evaluate for microdiscectomy and laminectomy. For MI-TLIF, chronology was not associated with repeat spins. (7) Incorrect localization: none. CONCLUSIONS: Skin-anchored ION did not result in any wrong level surgeries. Learning curve for other parameters varied by surgery type, but was achieved at 25-35 cases for a majority of outcomes. LEVEL OF EVIDENCE: Level III.

publication date

  • March 23, 2021

Research

keywords

  • Radiation Exposure
  • Spinal Fusion

Identity

Digital Object Identifier (DOI)

  • 10.1097/BSD.0000000000001167

PubMed ID

  • 33769982