Template-Directed Instrumentation Reduces Cost and Improves Efficiency for Total Knee Arthroplasty: An Economic Decision Analysis and Pilot Study. Academic Article uri icon

Overview

abstract

  • Template-directed instrumentation (TDI) for total knee arthroplasty (TKA) may streamline operating room (OR) workflow and reduce costs by preselecting implants and minimizing instrument tray burden. A decision model simulated the economics of TDI. Sensitivity analyses determined thresholds for model variables to ensure TDI success. A clinical pilot was reviewed. The accuracy of preoperative templates was validated, and 20 consecutive primary TKAs were performed using TDI. The model determined that preoperative component size estimation should be accurate to ±1 implant size for 50% of TKAs to implement TDI. The pilot showed that preoperative template accuracy exceeded 97%. There were statistically significant improvements in OR turnover time and in-room time for TDI compared to an historical cohort of TKAs. TDI reduces costs and improves OR efficiency.

publication date

  • May 12, 2015

Research

keywords

  • Arthroplasty, Replacement, Knee
  • Precision Medicine

Identity

Scopus Document Identifier

  • 84941880859

Digital Object Identifier (DOI)

  • 10.1016/j.arth.2015.04.043

PubMed ID

  • 26021908

Additional Document Info

volume

  • 30

issue

  • 10