Rotator cuff repair fluid extravasation characteristics are influenced by repair technique. Academic Article uri icon

Overview

abstract

  • BACKGROUND: This study evaluates rotator cuff repair fluid extravasation characteristics for different rotator cuff repair techniques. METHODS: Eight fresh-frozen cadaveric shoulders were dissected free of soft tissues, with the glenohumeral joint capsule and rotator cuff muscles being left intact. A custom fluid infusion device was used to deliver fluid at constant pressure into the glenohumeral joint. The shoulders were tested in conditions of (1) intact rotator cuff, (2) supraspinatus tear, (3) repaired supraspinatus tear with a single-row technique, and (4) repaired supraspinatus tear with a double-row suture bridge technique. RESULTS: The volume per minute of saline solution extravasation for single-row repair and double-row suture bridge repair was 48.53 mL/min and 11.73 mL/min, respectively, at 2 psi; 73.3 _ 24.1 mL/min and 24.5 _ 19.7 mL/min, respectively, at 3 psi; and 95.2 _ 22.6 mL/min and 39.2 _ 23.8 mL/min, respectively, at 4 psi. There was a statistically significant greater fluid extravasation for the single-row repair compared with the double-row suture bridge repair at all 3 pressures tested (P < .05). CONCLUSION: Single-row rotator cuff repair exposes the healing zone to greater extravasation of fluid compared with double-row suture bridge repair. Therefore, double-row repair potentially enhances rotator cuff healing. LEVEL OF EVIDENCE: Controlled laboratory study.

publication date

  • March 17, 2009

Research

keywords

  • Extravasation of Diagnostic and Therapeutic Materials
  • Rotator Cuff

Identity

Scopus Document Identifier

  • 70349739369

Digital Object Identifier (DOI)

  • 10.1016/j.jse.2009.01.020

PubMed ID

  • 19297198

Additional Document Info

volume

  • 18

issue

  • 6